This study introduces a dual-mode computational framework that utilizes twisted Moiré-integrated metamaterials to achieve high-precision terahertz refractive-index sensing of normal and pathological brain tissues.
The Moiré Supercell Meta-MXene architecture relies on rotational spatial symmetry breaking—induced by an 11.4° interlayer rotation and a 1 μm coupling gap—as the key physical trigger driving strong dipole-BIC hybridization.
Concurrently, the Meta-MXene layer folding inherent to the twisted supercell creates an emergent Moiré-signature resonance at 8.524 THz—a spectral feature entirely absent in unrotated geometries.
Further, the heterostructure exhibits remarkable tolerance under realistic fabrication deviations, restricting perturbations to \(\:{\Delta\:}\text{f}=0.072\:\text{T}\text{H}\text{z}\) and \(\:{\Delta\:}\text{Q}=5.146\) for the Moiré mode and \(\:{\Delta\:}\text{f}=0.12\:\text{T}\text{H}\text{z}\) and \(\:{\Delta\:}\text{Q}=\:3.09\:\:\)for the q-BIC mode, confirming robust electromagnetic field confinement.
By combining the high-gain sensitivity of the q-BIC state with the spectral resilience of the Moiré feature, this dual-mode framework overcomes single-resonance limitations, providing a label-free THz diagnostic pathway for early-stage brain pathologies.
This study introduces a dual-mode computational framework that utilizes twisted Moiré-integrated metamaterials to achieve high-precision terahertz refractive-index sensing of normal and pathological brain tissues. The Moiré Supercell Meta-MXene architecture relies on rotational spatial symmetry breaking—induced by an 11.4° interlayer rotation and a 1 μm coupling gap—as the key physical trigger driving strong dipole-BIC hybridization. This mechanism confirms the evolution of a non-radiating dark state into an accessible, highly localized quasi-Bound State in the Continuum (q-BIC), displaying a sharp reflection minimum of -40.147 dB at 9.948 THz. Concurrently, the Meta-MXene layer folding inherent to the twisted supercell creates an emergent Moiré-signature resonance at 8.524 THz—a spectral feature entirely absent in unrotated geometries. Numerical evaluations demonstrate that the primary q-BIC sensing channel achieves a peak Quality Factor (Q) of 28.62, whereas the induced Moiré mode acts as a stable reference benchmark with a peak Q of 42.66 and a baseline sensitivity of 208.6 GHz/RIU across the full refractive index span of brain tissue (1.333–1.483). For targeted pathological brain refractive-index sensing demonstration to discriminate healthy Gray Matter (n = 1.395) from highly aggressive Malignant Glioblastoma (n = 1.4470), the q-BIC resonance yields a localized diagnostic sensitivity of 462.4 GHz/RIU, supported by a 154.1 GHz/RIU sensitivity along the reference Moiré channel. Further, the heterostructure exhibits remarkable tolerance under realistic fabrication deviations, restricting perturbations to \(\:{\Delta\:}\text{f}=0.072\:\text{T}\text{H}\text{z}\) and \(\:{\Delta\:}\text{Q}=5.146\) for the Moiré mode and \(\:{\Delta\:}\text{f}=0.12\:\text{T}\text{H}\text{z}\) and \(\:{\Delta\:}\text{Q}=\:3.09\:\:\)for the q-BIC mode, confirming robust electromagnetic field confinement. By combining the high-gain sensitivity of the q-BIC state with the spectral resilience of the Moiré feature, this dual-mode framework overcomes single-resonance limitations, providing a label-free THz diagnostic pathway for early-stage brain pathologies.