The parameters assessed included Little’s Irregularity Index, Plaque Index, Gingival Index, probing depth, and bleeding on probing.
No statistically significant between-group differences were observed in the Plaque Index, Gingival Index (p = 0.415), or probing depth at any assessment.
No statistically significant between-group difference in bleeding on probing was observed on either buccal or palatal surfaces at any time point.
No statistically significant between-group differences were observed in the periodontal outcomes evaluated, including bleeding on probing.
Within the limitations of this short-term trial, the findings do not establish a general clinical or periodontal advantage of either retainer type.
Fixed retainer use has risen to ensure maxillary anterior alignment stability. The objective of this study is to compare the stability of maxillary anterior alignment and periodontal health at 3 and 6 months post-orthodontic treatment in patients using multistranded versus straight stainless steel fixed retainers, combined with a night-time vacuum-formed retainer. Single-center, 2-arm parallel randomized clinical trial with a 1:1 allocation ratio. Twenty-four patients were randomly assigned to receive either a multistranded retainer or a straight stainless steel retainer. Clinical evaluations were performed at appliance removal (T1), and at 3 (T2) and 6 (T3) months post-treatment. The parameters assessed included Little’s Irregularity Index, Plaque Index, Gingival Index, probing depth, and bleeding on probing. Little’s Irregularity Index increased slightly over time in both groups, but the changes during follow-up were not statistically significant, and no significant between-group difference in alignment changes was detected (p < 0.001). No statistically significant between-group differences were observed in the Plaque Index, Gingival Index (p = 0.415), or probing depth at any assessment. No statistically significant between-group difference in bleeding on probing was observed on either buccal or palatal surfaces at any time point. Although the straight stainless steel retainer group showed numerically higher palatal bleeding at 3 and 6 months, these differences were not statistically significant. During the first 6 months after orthodontic appliance removal, maxillary anterior alignment remained broadly stable in both retainer groups used with nighttime vacuum-formed retention. No statistically significant between-group differences were observed in the periodontal outcomes evaluated, including bleeding on probing. These short-term findings do not establish superiority of either retainer type. Within the limitations of this short-term trial, the findings do not establish a general clinical or periodontal advantage of either retainer type. Retainer selection should therefore consider the clinical context, operator experience, maintenance requirements, and patient adherence.
Trial registration: Rebec (Brazilian Register of Clinical Trials): RBR-7hwv8gj.